A |
Coating is resistant, for continuous immersion, against attack from the chemical listed. |
B |
Coating is resistant against attack from fumes of the chemical listed. For immersion service of the chemical, please refer to a coating with an A or LR listed or contact Heresite Protective Coatings. |
C |
Coating will provide the necessary 72 hours resistance required for secondary containment but is not recommended for continuous immersion. |
LR |
Limited Recommendation – contact Heresite Protective Coatings, Inc. for assistance. |
NR |
Coating is not recommended for the service conditions. |
Blank |
Coating has insufficient test data for the service conditions. |